Navigating New York’s Evolving Refrigerant Regulations
As refrigerant regulations continue to evolve, mechanical engineers are navigating new phase-out timelines, equipment considerations, and safety requirements. In "Phasing Forward: Navigating New York’s Evolving Refrigerant Regulations" for Engineering News-Record East, RMF's Eric Chrencik, PE examines these changing requirements and the technical considerations influencing chiller and heat pump system design, including how they are being addressed on RMF’s $16 million chiller upgrade project at the University at Albany.
Refrigerant selection is continuing to shift as federal and state regulations target refrigerants with higher global warming potential (GWP). In New York, DEC Part 494 establishes additional restrictions and phase-out dates that affect refrigerants currently used in commercial and industrial HVAC equipment. Among these requirements, f-gases with a 20-year GWP greater than 20 will be phased out for all chillers beginning January 1, 2030, while all heat pump chillers face that threshold beginning January 1, 2034.
In the article, Eric Chrencik, PE outlines how these changing requirements affect more than refrigerant selection. Replacement refrigerants can impact equipment capacity, and some newer options are classified as A2L refrigerants, which are low toxicity and mildly flammable and require additional safety considerations. ASHRAE 15 includes specific requirements for A2L refrigerants, including ventilation requirements tied to refrigerant detection.
Chrencik also examines these considerations through RMF Engineering’s current $16 million chiller upgrade project at the University at Albany. The project is replacing two aging absorption chillers in a 1960s-built central power plant with high-efficiency electric centrifugal chillers. Because New York’s DEC Part 494 regulations were finalized while design was underway, the project team had to account for refrigerant phase-out schedules, equipment capacity, physical space within the existing plant, and future refrigerant availability.
The project also includes upgrades to the plant’s refrigerant detection and exhaust systems, including new leak detection monitoring equipment and upsized exhaust fans. These improvements address the quantity of refrigerant in the new chillers while maintaining compliance with ASHRAE 15 and supporting a safe working environment within the plant.
Looking beyond New York, the article notes that states including California and Washington have also begun finalizing requirements that exceed federal EPA standards. As regulations and refrigerant technologies continue to change, HVAC engineers will need to account for phase-out timelines, equipment and ventilation requirements, and the technical implications of alternative refrigerants when advising clients and designing systems.
Read the full ENR East Viewpoint article here: "Phasing Forward: Navigating New York’s Evolving Refrigerant Regulations."